Model Efficiency - AFUE : Input : Heating Capacity : Net I=B=R Rating : Height : Width : Depth : Shipping Weight : Fuel Type : Warranty : Electrical Supply : Vent pipe : Vent pipe (continued) : Air intake : Water In/Out : Gas In : Condensate Drain :
Q90-50 90% 50 MBH 45 MBH 39 MBH 39.5" 28" 19.75" 220 lbs Natural or LP Gas 15 Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps First 5' is schedule 40 2" CPVC (provided), then schedule 40 2" or 3" PVC Schedule 40 2" or 3" PVC 1-1/4" NPT 1/2" NPT 1/2" PVC
Q90-75 90% 75 MBH 68 MBH 59 MBH 39.5" 28" 19.75" 220 lbs Natural or LP Gas 15 Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps first 5' is schedule 40 2" CPVC (provided), then schedule 40 2" or 3" PVC schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q90-100 90% 78 MBH 39.5" 28" 19.75" 220 lbs Natural or LP Gas 15-Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps First 5' is schedule 40 2" CPVC (provided), Then schedule 40 2" or 3" PVC Schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q90-125 90% 125 MBH 112.5 MBH 98 MBH 40.25" 32.25" 20.125" 220 lbs Natural or LP Gas 15 Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps First 5' is schedule 40 2" CPVC (provided), Then schedule 40 2" or 3" PVC Schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q90-150 90% 150 MBH 135.0 MBH 117 MBH 40.25" 32.25" 20.125" 220 lbs Natural or LP Gas 15-Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps first 5' is schedule 40 2" CPVC (provided), Then schedule 40 2" or 3" PVC Schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q90-175 90% 175 MBH 157.5 MBH 137 MBH 40.25" 32.25" 20.125" 220 lbs Natural or LP Gas 15 Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps first 5' is schedule 40 2" CPVC (provided), Schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q90-200 90% 200 MBH 180.0 MBH 157 MBH 40.25" 32.25" 20.125" 220 lbs Natural or LP Gas 15 Year Limited Heat Exchanger 120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps First 5' is schedule 40 2" CPVC (provided), Then schedule 40 2" or 3" PVC Schedule 40 2" or 3" PVC 1.25" NPT .5" NPT .5" PVC
Q95M-200 200 38" 18" 31" Natural gas or propane 15-Year Limited Heat Exchanger Warranty 120 Volts AC, 60 Hertz, 1 Phase, Less Then 12 Amps 1.25” NPT .5” NPT .5” PVC

6637 Arctic Spur Road, Anchorage, Alaska 99518
Phone 907.278.7441· Fax 1.888.408.7330
contact us
© 2000, Rural Energy Enterprises, Inc.