| Model |
Efficiency - AFUE : |
Input : |
Heating Capacity : |
Net I=B=R Rating : |
Height : |
Width : |
Depth : |
Shipping Weight : |
Fuel Type : |
Warranty : |
Electrical Supply : |
Vent pipe : |
Vent pipe (continued) : |
Air intake : |
Water In/Out : |
Gas In : |
Condensate Drain : |
|
Q90-50 |
90% |
50 MBH |
45 MBH |
39 MBH |
39.5" |
28" |
19.75" |
220 lbs |
Natural or LP Gas |
15 Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
First 5' is schedule 40 2" CPVC (provided), |
then schedule 40 2" or 3" PVC |
Schedule 40 2" or 3" PVC |
1-1/4" NPT |
1/2" NPT |
1/2" PVC |
|
Q90-75 |
90% |
75 MBH |
68 MBH |
59 MBH |
39.5" |
28" |
19.75" |
220 lbs |
Natural or LP Gas |
15 Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
first 5' is schedule 40 2" CPVC (provided), |
then schedule 40 2" or 3" PVC |
schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q90-100 |
90% |
78 MBH |
39.5" |
28" |
19.75" |
220 lbs |
Natural or LP Gas |
15-Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
First 5' is schedule 40 2" CPVC (provided), |
Then schedule 40 2" or 3" PVC |
Schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q90-125 |
90% |
125 MBH |
112.5 MBH |
98 MBH |
40.25" |
32.25" |
20.125" |
220 lbs |
Natural or LP Gas |
15 Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
First 5' is schedule 40 2" CPVC (provided), |
Then schedule 40 2" or 3" PVC |
Schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q90-150 |
90% |
150 MBH |
135.0 MBH |
117 MBH |
40.25" |
32.25" |
20.125" |
220 lbs |
Natural or LP Gas |
15-Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
first 5' is schedule 40 2" CPVC (provided), |
Then schedule 40 2" or 3" PVC |
Schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q90-175 |
90% |
175 MBH |
157.5 MBH |
137 MBH |
40.25" |
32.25" |
20.125" |
220 lbs |
Natural or LP Gas |
15 Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
first 5' is schedule 40 2" CPVC (provided), |
Schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q90-200 |
90% |
200 MBH |
180.0 MBH |
157 MBH |
40.25" |
32.25" |
20.125" |
220 lbs |
Natural or LP Gas |
15 Year Limited Heat Exchanger |
120 Volts AC, 60 Hertz, 1 Phase, Less than 12 Amps |
First 5' is schedule 40 2" CPVC (provided), |
Then schedule 40 2" or 3" PVC |
Schedule 40 2" or 3" PVC |
1.25" NPT |
.5" NPT |
.5" PVC |
|
Q95M-200 |
200 |
38" |
18" |
31" |
Natural gas or propane |
15-Year Limited Heat Exchanger Warranty |
120 Volts AC, 60 Hertz, 1 Phase, Less Then 12 Amps |
1.25” NPT |
.5” NPT |
.5” PVC |